产品信息
荧光素标记
FITC
抗原名称
CD8
宿主
Mouse IgG2a, κ
简单描述
The G42-8 monoclonal antibody specifically recognizes the alpha subunit (32 kDa) of CD8αα homodimer or CD8αβ heterodimer. The CD8 molecule binds to HLA class I molecules during interaction of CD8+ T cells with antigen-presenting cells or target cells. CD8 is expressed on T cytotoxic/suppressor cell populations. G42-8 stains approximately 13-48% of peripheral blood lymphocytes and 80% of thymocytes, as well as a subset of NK cells. This antibody is useful in detecting CD8+ T cells when using DimerX I reagents.
商品描述
The G42-8 monoclonal antibody specifically recognizes the alpha subunit (32 kDa) of CD8αα homodimer or CD8αβ heterodimer. The CD8 molecule binds to HLA class I molecules during interaction of CD8+ T cells with antigen-presenting cells or target cells. CD8 is expressed on T cytotoxic/suppressor cell populations. G42-8 stains approximately 13-48% of peripheral blood lymphocytes and 80% of thymocytes, as well as a subset of NK cells. This antibody is useful in detecting CD8+ T cells when using DimerX I reagents.
同种型
Mouse IgG2a, κ
克隆号
G42-8
浓度
0.5 mg/ml
产品详情
FITC
Fluorescein (FITC) is part of the BD blue family of dyes. This is a small organic fluorochrome with an excitation maximum (Ex Max) at 494-nm and an emission maximum (Em Max) at 518-nm. FITC is designed to be excited by the Blue laser (488-nm) and detected using an optical filter centered near 520 nm (e.g., a 530/30-nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
FITC
Blue 488 nm
494 nm
518 nm
应用
实验应用
Flow cytometry (Routinely Tested)
反应种属
Human (QC Testing)
背景
别名
CD8α; CD8A; CD8 alpha; Leu2; MAL; T8; p32
制备和贮存
存储溶液
Aqueous buffered solution containing ≤0.09% sodium azide.
保存方式
Aqueous buffered solution containing ≤0.09% sodium azide.
文献
文献
研发参考(1)
1. Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995.
数据库链接
Entrez-Gene ID
925
参考图片
Flow cytometric analysis of CD8 expression on peripheral blood lymphocytes. Whole blood was stained with either FITC Mouse IgG2a, κ Isotype Control (Cat. No. 555573; dashed line histogram) or FITC Mouse Anti-Human CD8 (Cat. No. 551347; solid line histogram). Erythrocytes were lysed with Lysing Buffer (Cat. No. 555899).The fluorescence histogram was derived from gated events with the forward and side light-scattering characteristics of viable cells.
本文来自投稿,不代表本人立场,如若转载,请注明出处:http://www.iamyjet.com/kangti/8933.html